Pointe Scientific 180 Chemistry Analyzer (11080)

Specialty: General Chemistry


Welcome to the PulseAid listing for the Pointe Scientific 180 Chemistry Analyzer medical device. This device is used in the General Chemistry healthcare specialty. Below, you can view the analytes this device is used to test, and its corresponding complexity (HIGH, MODERATE, or CLIA WAIVED). We have also randomly listed additional medical devices used in the General Chemistry healthcare specialty at the bottom of the page.

Analytes Measured/Detected and Complexity:

ANALYTECOMPLEXITY
Acid phosphatase (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Alanine aminotransferase (ALT) (SGPT) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Albumin (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Alkaline phosphatase (ALP) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Amylase (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Aspartate aminotransferase (AST) (SGOT) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Bilirubin, direct (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Bilirubin, total (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Calcium, total (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Carbon dioxide, total (CO2) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Chloride (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Cholesterol (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Creatine kinase (CK) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Creatinine (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Digoxin (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Gamma glutamyl transferase (GGT) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Glucose (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Glycosylated Hemoglobin (Hgb A1c) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
HDL cholesterol (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Hemoglobin (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Iron (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Iron binding capacity (post saturation/separation) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Lactate dehydrogenase (LDH) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Lipase (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Magnesium (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Phosphorus (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Potassium (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Protein, total (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Theophylline (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Thyroid stimulating hormone (TSH) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Thyroxine (T4) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Triglyceride (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Triiodothyronine uptake (T3U) (TU) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Urea (BUN) (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26
Uric acid (CDC000212 | CDC000212) HIGH
Effective Date: 1993-07-26

Other General Chemistry Devices:

Medical DeviceComplexity
Olympus AU400eView Complexity
Wako Cholesterol CII Assay KitView Complexity
Beckman Coulter, Inc., Synchron LX I 725 Clinical SystemView Complexity
Siemens Dimension Vista 1000TView Complexity
Polymer Technology Systems, Inc., CardioChek Home Test SystemView Complexity
Du Pont ACA IIView Complexity
Thermo Electron, DPC T60 AnalyzerView Complexity
Osmetech, Inc OPTI R Blood Gas AnalyzerView Complexity
Beckman Coulter AU680 Chemistry AnalyzerView Complexity
Siemens Dimension EXL with LM SystemView Complexity